Answer:
|
- Start the u-center to configure the settings of Port and Baud rate
- Select View->Messages View, and then a window will pop out. Select UBX->CFG(Config)->RATE(Rates)
- Enter “200” in the option Measurement Period
- Click the button Send to transmit the command to the GPS module. Now, the update rate is modified to 5Hz.
- For data save on power down, select UBX->CFG(Config)->CFG(Configuration)
- Select the option Save current configuration, and then choose the option 2-I2C-EEPROM in the Devices box.
- Click the button Send to save the current configuration to EEPROM.
|
|