WSSP08A

From Waveshare Wiki
Revision as of 03:55, 5 January 2021 by Waveshare-eng11 (talk | contribs) (Created page with "{{Infobox item| |name=WSSP08A |img=400px|link=https://www.waveshare.com/wssp08a.htm|WSTP11A |caption=Industrial 2.5MPa Pressure Transmitter, RS485 Bus |...")
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search
The printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.
WSSP08A
WSTP11A

Industrial 2.5MPa Pressure Transmitter, RS485 Bus
{{{name2}}}

{{{name3}}}

{{{name4}}}

{{{name5}}}

Industrial 2.5MPa Pressure Transmitter, Grade-A Diffused Silicon Transducer, RS485 Bus, Hydraulic / Barometric / Oil Pressure Sensor

Features

  • Digital output, via RS485 (standard Modbus-RTU protocol)
  • Film isolation technology, features corrosion-resistant and obstruction-proof, effectively extend the instrument lifespan
  • Integrated chip, small size, easy installation, and wide range input voltage
  • IP65 protection rate,cut-off frequency design, strong anti-interference capability
  • Protections including current limited, voltage limited, reverse proof (limited output current)
  • Measurement accuracy up to 0.5% FS

Specification

  • Measured Medium:Liquid, gas (compatible with contact material)
  • Accuracy: 0.5%FS
  • Overload: 200% full range
  • Full weight: 190±5g
  • Shock resistant: 10g (20~2000HZ)
  • Stability: ±0.2% FS/year
  • Pressure range: 0~2.5MPa gauge pressure
  • Protection rating: IP65
  • Power supply: 12~24V DC
  • TEMP.Comprensation: --10~70℃
  • TEMP.Drift:±0.2% FS/℃ (in compensation range)
  • Output signal: RS485 (standard Modbus-RTU protocol)
  • Operating environment:
    • Medium temperature: -40~85℃
    • Ambient temperature: -40~85℃
    • Ambient humidity: 0%~95% RH (non-condensing, non-frosting)
  • Material:
    • Film: 316L stainless steel (contacted)
    • Intermediate junction: 304 stainless steel (contacted)
    • Shell: 304 stainless steel
    • Sealing: Buna-N rubber (contacted)
    • Hirschmann connector: ABS engineering plastics

Interface

WSSP08A uses a standard RS485 interface. RS485 supports multi-point, duplex communication, it allows multiple transmitters to be connected o the same bus.

Hesman interface
1 V+(12V~26V)
2 A
3 V-(GND)
4(Gnd.png) B

Communication Protocol

Modbus protocol is a universal language used in industrial electronic controllers. Modbus supports communication to and from multiple devices connected to the same cable or Ethernet network, it has become a standard communication protocol. With the Modbus, control equipment produced by different manufactures can be connected to the sam industrial network for centralized monitoring. The protocol defines a message structure, which can be recognized and used by the controller through any network. It describes the process of a controller requesting access to other devices, how to respond to requests from other devices, and how to detect and record errors. It has formulated a common format for the structure and content of the message domain.
Advantage of Modbus: (1)It is a standard protocol, open-sources, and free to use. (2)Modbus protocol support RS-232, RS-485 bus, and so on. (3)The format of Modbus is simple and easy to use.

Modbus parameters of WSSP08A (the device address is default 01)

This sensor is compatible with Modbus RTU. The RS485 port is half-duplex.
a) Output signal: RS485 (Communication distance is up to 1000m. Support multi-connect 32 devices)
b) Standard Modbus-RTU protocol (03: Read data; 06: Write setting data)<br /? c) Data format: 9600, N, 8, 1
d) Measure range: 0-X(MPa, kPa...)
e) Accuracy: 0.05%
f) Output data: 0...2000(range is customizable)
g) Response frequency: ≤5Hz
h) Response speed: ≥10ms

0x03: Read data (HEX)

WSSP08A format-1.png

Examples 1
Read sensor

The device address of 0-1.6Mpa sensor is 0x01, that is [Address]=01 (The Address range 01-254)
CRC0=84 and CRC1=0a, then the commands will be:
Command: 01 03 00 00 00 01 84 0A
Response: 01 03 02 02 AC B9 59
Convert 02AC to DEC, you will get the data 684;
Because the data range is 0-2000, related to the pressure range 0-1.6Mpa, the pressure read is P = 1.6*684/2000=0.5472MPa
The formula: (The maximum range - the minimum range) /2000 * Current data + minumin ranage = current pressure.

Examples 2
Read device address (This command only work for a single sensor)

Command: FF 03 00 0F 00 01 A1 D7
Response: FF 03 02 00 01 50 50
That is: The device address is 01

0x06: Write data (HEX)

WSSP08A format-2.png

Examples
Modify the device address from 01 to 09

Command: 01 06 00 0F 00 09 79 CF
Response: 01 06 00 0F 00 09 79 CD
The modification will be valid without a restart.

Connection

Pull out the terminal block which is inside the casing of the plug to connect the wire, wiring steps areas shown in the following figure.
WSSP08A connect-1.png

Wiring diagram

WSSP08A connect-2.png

We use 2-CH RS485 HAT(should purchase separately) and Raspberry Pi for testing. For more information about how to use the 2-CH RS485 HAT, you can refer to 2-CH RS485 HAT

Hardware connection

Hesman Connector
1 V+(12V~36V)
2 A(Change 2)
3 V-(GND)
4(Gnd.png) B(Change 2)


PIN Raspberry Pi(BCM) Description
VCC 5V 3.3V/5V
GND GND GND
SCLK P21(SPI1 SCLK) SPI clock input
MOSI P20(SPI1 MOSI) SPI Data input
MISO P19(SPI1 MISO) SPI Data Output
CS P18(SPI1 CS) SPI chip selection
IRQ P24 Inttrupt pin
EN1 P27 Channel 1(Channel 1) enable pin: High: Send enable; Low: Receive enable
EN2 P22 Channel 2(Channel 2) enable pin: High: Send enable; Low: Receive enable

Install Driver

  • Open a terminal and run the commands:
sudo nano /boot/config.txt
#Add the following lines to file. Note that the ini_pin should be same as the actual define.
dtoverlay=sc16is752-spi1,int_pin=24
#Reboot
sudo reboot

After reboot, The SC16IS752 drive is installed in kernel, you can check the device by command ls /dev:
2-CH-RS485-HAT-3.png
If the kernel version is 5.4 or obove, the gpiochip3 is recognized as gpiochip2

Install Libraries

  • Install wiringPi
sudo apt-get install wiringpi
cd /tmp
wget https://project-downloads.drogon.net/wiringpi-latest.deb
sudo dpkg -i wiringpi-latest.deb
gpio -v
# Check if it is 2.52 version
  • Install python2 libraries
sudo apt-get update
sudo apt-get install python-pip
sudo pip install RPi.GPIO
sudo apt-get install python-serial
sudo apt-get install python-crcmod
  • Install python3 libraries
sudo apt-get update
sudo apt-get install python3-pip
sudo pip3 install RPi.GPIO
sudo apt-get install python3-serial
sudo apt-get install python3-crcmod

Testing

  • Download and run the demo codes
sudo apt-get install p7zip-full
sudo wget https://files.waveshare.com/upload/1/1a/WSSP08A_Code.7z
sudo 7z x WSSP08A_Code.7z
sudo chmod 777 -R WSSP08A_Code
cd WSSP08A_Code/
  • C example
cd c
make clean
make
sudo ./main
  • python example
#python2
cd python 
cd examples
sudo python main.py
#python3
cd python 
cd examples
sudo python3 main.py

About the Codes

  1. The demo codes are made for a situation that only one sensor is connected, it will read data according to the device address and it can be used to modify the device address.

WSSP08A run.png

  • C codes
#Read the device address (only one device is connected to RS485 bus)
uint8_t WSSP08A_get_addr(void)
#Modify the address of target device
uint8_t WSSP08A_set_addr(uint8_t o_addr, uint8_t n_addr)
#Read the data from target device
float WSSP08A_get_pressure(uint8_t addr)
  • python codes
#Get 16CRC result
def crc16Add(self,read):
#Read the device address (only one device is connected to RS485 bus)
def get_addr(self):
#Read the data from target device
def get_press(self,addr):
#Modify the address of target device
def set_addr(self,o_addr,s_addr):

Support

If you require technical support, please go to the Support page and open a ticket.