CAN FD Protocol Converter, CAN FD To ETH/RS232/RS485 Bidirectional Data Communication, Supports 5 Data Conversion Modes And CAN 2.0A/2.0B Protocols, Heartbeat And Registration Packets Support

SKU:32600
Part No.:CAN FD ETH RS232/RS485 Converter
Brand:Waveshare

¥9,613
PriceQuantity
1
¥9,4202
¥9,3243
¥9,2864+
Related Products:

Details

CAN FD Protocol Converter, CAN FD To ETH/RS232/RS485 Bidirectional Data Communication, Supports 5 Data Conversion Modes And CAN 2.0A/2.0B Protocols, Heartbeat and registration packets support
CAN FD Protocol Converter

CAN FD Protocol | 5 Data Conversion Modes | Industrial Performance



CAN FD ETH RS232/RS485 Converter, front view
Features at a glance

The CAN FD ETH RS232/RS485 Converter is a DIN-rail CAN FD to Ethernet/RS232/RS485 bidirectional converter, featuring high-speed, low-latency, stable performance, ease of use, and cost-effectiveness. It supports five data conversion modes: transparent conversion, transparent conversion with ID, standard protocol conversion, Modbus protocol conversion, and custom protocol conversion. Enables interconnection between CAN and Network port / serial port devices, compatible with CAN FD and CAN 2.0A/2.0B protocols.

Features industrial-grade design, supports -40°C ~ 85°C stable working, 9V ~ 36V wide power input, 5Kbps~1Mbps CAN FD arbitration domain baud rate, and 100Kbps~5Mbps CAN FD data domain baud rate.

Supports parameter configuration via host computer, built-in 120Ω terminal resistors (switchable via DIP switches), supports DIN-rail mounting, easy to configure and install.

Specifications
Classify Parameter Describe
Parameter Working voltage DC 9V ~ 36V
Size 110 × 27 × 85.6 (mm)
Way to install DIN-rail installation
Reload button Long press to restore factory settings
Indicator light POWER, WORK, COM and CAN
Interface Parameters CAN port specification 1-ch CAN port, supports CAN FD, compatible with CAN 2.0A/2.0B
CAN port baud rate Arbitration domain baud rate: 5Kbps ~ 1Mbps
Data domain baud rate: 100Kbps ~ 5Mbps
Terminal resistor Built-in 2 × 120Ω terminal resistors,
Switching either DIP switch to ON connects one 120 Ω resistor in parallel.
Switching both to ON connects two 120Ω resistors in parallel
Networkport specifications RJ45, 10/100Mbps, Cross-connection adaptive
Serial port specification Supports 1-ch RS485 or RS232
Work Environment Working temperature -40℃ ~ 85℃
Storage temperature -40℃ ~ 105℃
Working humidity 5% ~ 95% RH (no condensation)
Storage humidity 5% ~ 95% RH (no condensation)
Software Function Networking protocol TCP server, TCP client, UDP server, UDP client (only network port)
Modbus gateway Network port: CAN FD to Modbus TCP (Master/Slave)
Serial port: CAN FD To Modbus RTU (Master/Slave)
Send the message Supports up to 64 transmit messages
Receive messages Supports up to 64 receiving messages
Protocol conversion Transparent conversion, transparent conversion with ID, standard protocol conversion, Modbus protocol conversion, and custom protocol conversion
CAN ID Supports standard frame and extended frame
Frame ID filtering Supports only standard frames, only extended frames, and custom input frame ID (up to 32 groups)
Pack frame time Supports customizing the number of frames and the time of frame packing (network port)
Change direction Supports bidirectional conversion, only serial/Ethernet port to CAN, and only CAN to serial/Ethernet port;
Firmware upgrade Supports the host computer for firmware upgrade
Parameter configuration AT instruction and host computer software configuration
Other features Support heartbeat packets; register packets; normal, loopback, and only listen modes (network port)
Protection Parameters ESD Protection Air discharge: 8 KV, Contact discharge: 6 KV
Eft/Burst Power circuit: 2KV; RS485/RS232 circuit: 1KV; Network port & CAN port circuit: 1KV
Surge Immunity Test Power circuit: 1KV differential mode, 2KV common mode;
CAN circuit: 2KV common mode;
Serial port & Network port circuit: 2KV common mode;

Basic Function

supports CAN FD To ETH/RS232/RS485 Bidirectional Data Communication

CAN FD ETH RS232/RS485 Converter, basic functions

arbitration domain baud rate

CAN FD arbitration domain baud rate : 5Kbps ~ 1Mbps

CAN FD ETH RS232/RS485 Converter, arbitration domain baud rate
data domain baud rate

CAN FD data domain baud rate:100Kbps ~ 5Mbps

CAN FD ETH RS232/RS485 Converter, data domain baud rate
Industrial-grade design
CAN FD ETH RS232/RS485 Converter, Industrial-grade design
Supports multiple conversion modes

Transparent conversion, transparent conversion with ID, standard conversion, Modbus protocol conversion, and custom frame headers and trailers conversion

CAN FD ETH RS232/RS485 CONVERTER, Supports multi conversion modes

Transparent conversion

Achieve original conversion between CAN FD frames and serial/Ethernet frames

CAN FD ETH RS232/RS485 Converter, Transparent conversion

Transparent Conversion with ID

Transfer the ID information in serial/Ethernet frames to CAN FD frames

CAN FD ETH RS232/RS485 Converter, Transparent Conversion with ID

Standard Conversion

Conversion between 13-byte standard CAN frame format and 69-byte standard CAN FD frame format

CAN FD ETH RS232/RS485 Converter, Standard Conversion

Modbus Protocol Conversion

Realize Modbus data transmission over CAN bus through packet segmentation and reassembly

CAN FD ETH RS232/RS485 Converter, Modbus Protocol Conversion

Custom protocol conversion

Users can customize frame headers and trailers to enable bidirectional data conversion

CAN FD ETH RS232/RS485 Converter, Custom protocol conversion

3 Frame Filtering Methods, 32 Sets of Configurable Filters

Supports Only Receive Extended Frame, Only Receive Standard Frame, and Custom Receive Frame ID. In custom mode, users can set up to 32 sets of filter methods to avoid large amounts of data interference

CAN FD ETH RS232/RS485 Converter, 3 Frame Filtering Methods, 32 Sets of Configurable Filters

Configuration parameters via host computer

CAN FD ETH RS232/RS485 Converter, Configuration parameters via AT commands/host computer


Function Overview

Heartbeat Packet Function *

CAN Heartbeat Packet: Acts as a fixed query command, sending heartbeat packets through the CAN network.
Network Heartbeat Packet: Notifies the server that the device is active and maintains a stable network connection with the server.

CAN FD ETH RS232/RS485 Converter, Supports Heartbeat Packet Function

* when using the Ethernet port and CAN as data channels

Registration Packet Function *

Allows the server to identify the source device of incoming data, or serves as an authentication key for the device to access the server’s authorized functions.

CAN FD ETH RS232/RS485 Converter, Supports Registration Packet Function

* when using the Ethernet port and CAN as data channels


Application Scenarios
CAN FD ETH RS232/RS485 Converter, BMS Battery Monitoring

BMS Battery Monitoring

CAN FD ETH RS232/RS485 Converter, Industrial Automation

Industrial Automation

CAN FD ETH RS232/RS485 Converter, EV charging

EV Charging

CAN FD ETH RS232/RS485 Converter, Traffic Monitoring

Traffic Monitoring

Interface introduction

CAN FD ETH RS232/RS485 Converter, Interface introduction
Outline dimensions
CAN FD ETH RS232/RS485 Converter, Outline dimensions
CAN FD Converter Selection

型号CAN FD TO ETHCAN FD TO RS232/RS485CAN FD ETH RS232/RS485 Converter
Product Type CAN FD to ETH CAN FD to RS485/RS232 CAN FD to ETH/RS485/RS232
CAN FD Supported
EMC Protection Level 3 Level 3 Level 3, fully isolated power/interface/communication
External Structure Aluminum extrusion, DIN-rail
conversion modes 5
Frame ID filtering 32 groups
Modbus Modbus TCP (Master/Slave) Modbus RTU (Master/Slave) Modbus TCP (Master/Slave)
Modbus RTU (Master/Slave)

Weight: 0.143 kg

Quick Overview

The power supply is not included, it is recommended to use with a 12V Power Adapter

  1. CAN FD ETH RS232/RS485 Converter x1
  2. Power plug adapter x1
  3. Screwdriver x1
1 CAN FD ETH RS232/RS485 Converter x1
2 Power Plug Adapter x1
3 Screwdriver x1